Dual mains input Increases availability by allowing the UPS to be connected to two separate power sources.
Scalable runtime Allows additional run time to be quickly added as needed.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Generator compatible Ensures clean, uninterrupted power to protected equipment when generator power is used.
Automatic internal bypass Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Battery modules connected in parallel Delivers higher availability through redundant batteries.
Serviceability User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Battery replacement without tools Allows quick, easy battery replacement. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Shippable with modules installed Enables pre-installation UPS staging and testing and faster installation.
Modular design Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Manageability Network manageable Provides remote management of the UPS over the network. InfraStruXure Manager Compatible Enables centralized management via the APC InfraStruXure Manager.
LCD display Alpha-Numeric Display which displays system parameters and alarms.
Audible alarms Provides notification of changing utility power and UPS conditions
Programmable frequency Ensures compatibility with different input frequencies.
LED status indicators Quickly understand unit and power status with visual indicators.
SmartSlot Customize UPS capabilities with management cards.
Total Cost of Ownership Input power factor correction Minimizes installation costs by enabling the use of smaller generators and cabling.
Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Manual maintenance bypass Reduces installation costs by eliminating the need for an external mechanical bypass.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
Protection Frequency and voltage regulation Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Cold-start capable Provides temporary battery power when the utility power is out.
Specification:
Power |
---|
Output power capacity | 30 kVA |
Input frequency | 60 Hz |
Performance |
---|
Audible alarm modes | Battery replacement |
LED indicators | Yes |
Audible alarm(s) | Yes |
Features |
---|
Audible alarm modes | Battery replacement |
Audible alarm(s) | Yes |
Output power capacity | 30 kVA |
Input frequency | 60 Hz |
Battery |
---|
Hot-swap battery | Yes |
Cold start | Yes |
Automatic battery test | Yes |
Design |
---|
Form factor | Tower |
LED indicators | Yes |
Product colour | Black |
Certification | UL 1778 |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | 0 - 45 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 118110.2" (0 - 3000 m) |
Non-operating altitude | 0 - 354330.7" (0 - 9000 m) |
Packaging data |
---|
Package dimensions (WxDxH) | 28.5 x 43.5 x 65.5" (723 x 1104 x 1663 mm) |
Package weight | 804.7 lbs (365 kg) |
Weight & dimensions |
---|
Weight | 731.9 lbs (332 kg) |
Width | 13.8" (351 mm) |
Height | 58.5" (1487 mm) |
Depth | 33" (837 mm) |
Package weight | 804.7 lbs (365 kg) |
Certificates |
---|
Certification | UL 1778 |
Other features |
---|
Package dimensions (WxDxH) | 28.5 x 43.5 x 65.5" (723 x 1104 x 1663 mm) |
Nominal output voltage | 208 V |
Nominal input voltage | 208 V |