Double-Conversion UPS Protects Equipment against Damage, Downtime and Data Loss This 200/208/220/230/240V 50/60 Hz UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC with +/-2% voltage regulation in online and battery modes. Featuring a 900W capacity, high 0.9 power factor, 627 joules of surge suppression, true on-line operation with pure sine wave output and zero transfer time to battery mode in on-line double-conversion mode, the SmartOnline® SUINT1000LCD2U double-conversion UPS provides the highest level of AC power protection and battery backup for critical network closet, computer room and data center equipment.
Set Power Strategies to Reflect Your Protection Priorities Pick your power strategy, from precise power for sensitive systems to the highest possible electrical efficiency, while ensuring 100% uptime. Choose from five selectable strategies: Max Efficiency, Max Quality, Frequency Regulation, Frequency Conversion and Auto Adaptive, which automatically offers increased efficiency when power conditions are good and enhanced power quality when power conditions are poor.
Individually Controllable Load Banks Let You Access and Control Outlets Remotely Four C13 outlets are split evenly into two switchable load banks, allowing you to reboot select components or shed loads remotely. In addition to those four outlets, this UPS provides two more C13 outlets in their own unswitched bank for powering critical components.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable internal battery (RBC24S) provides 12.3 minutes of support at half load (450W) and 4.7 minutes at full load (900W), keeping protected equipment operational through power failures. For mission-critical applications demanding scalable extended runtime, the UPS supports “smart” external battery packs, such as Tripp Lite’s BP24V36-2US (sold separately). Both the internal and external batteries are automatically sensed and configured during replacement to offer accurate runtime-remaining and battery age notifications. The intelligent battery management system with temperature-compensated charging extends battery life.
Automatic Bypass Maintains Utility Output During Fault Conditions Auto-bypass mode keeps connected equipment powered and operational, even during UPS fault conditions.
ENERGY STAR-Certified Economy Mode Helps You Save Money and Protect the Environment By meeting strict EPA efficiency guidelines, this ENERGY STAR-certified UPS system helps you save money and energy. A power-saving Economy mode setting option offers enhanced efficiency and reduced BTU output when utility power is already high quality.
Automatically Turns Back On After Power Is Restored Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement.
Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The front-panel LCD screen reports UPS operating mode, detailed UPS status and site-power information, as well as a variety of advanced UPS setup and configuration options. LEDs indicate AC input/output, battery and fault status.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and HID-compliant USB ports connect to a computer running Tripp Lite’s free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. An EPO port connects the UPS to a contact closure switch to enable emergency inverter shutdown. Cables are included.
Optional WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control The optional WEBCARDLX (sold separately) with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Auto Probe allows a UPS with switched loads to automatically reboot devices if a network communication failure is detected.
Versatile Installation Options Hardware is included for mounting the UPS system in 2U of space in an EIA-standard 19-inch 4-post rack. Use the optional 2POSTRMKITWM (sold separately) for 2-post rack mounting or the optional 2-9USTAND (sold separately) for mounting in an upright tower position. The C14 power inlet accepts a variety of user-supplied input cords.
Specification:
Power |
---|
Output frequency | 50/60 Hz |
Output voltage regulation | 2% |
Output power | 900 W |
Input operation voltage (min) | 200 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 627 J |
Emergency Power Off (EPO) | Yes |
Power factor | 0.9 |
Crest factor | 3:1 |
Output power capacity | 1 kVA |
Input frequency | 50/60 Hz |
Performance |
---|
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Number of input phases | 1 |
LED indicators | Yes |
EMI/RFI noise filtering | Yes |
Surge protection features | Digital Subscriber Line (DSL), Network |
Noise level | 45 dB |
Audible alarm(s) | Yes |
Features |
---|
Output frequency | 50/60 Hz |
Country of origin | China |
Audible alarm modes | Alarm when on battery, Fault, Low battery alarm, Overload alarm |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Output voltage regulation | 2% |
Number of input phases | 1 |
Output power | 900 W |
Input operation voltage (min) | 200 V |
Input operation voltage (max) | 240 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Surge energy rating | 627 J |
EMI/RFI noise filtering | Yes |
Surge protection features | Digital Subscriber Line (DSL), Network |
Emergency Power Off (EPO) | Yes |
Power factor | 0.9 |
Noise level | 45 dB |
Crest factor | 3:1 |
Audible alarm(s) | Yes |
Output power capacity | 1 kVA |
Input frequency | 50/60 Hz |
Ports & interfaces |
---|
Emergency Power Off (EPO) connector | Yes |
USB port | Yes |
AC outlets quantity | 6 AC outlet(s) |
AC outlet types | C13 coupler |
Power plug | C14 coupler |
USB 2.0 ports quantity | 3 |
RS-232 ports | 1 |
Modem (RJ-11) ports | 1 |
Ethernet LAN (RJ-45) ports | 3 |
Battery |
---|
Typical backup time at half load | 12.3 min |
Typical backup time at full load | 4.7 min |
Hot-swap battery | Yes |
Cold start | Yes |
Design |
---|
Country of origin | China |
Rack capacity | 2U |
Form factor | Rackmount/Tower |
LED indicators | Yes |
Product colour | Black |
Cooling type | Active |
Certification | CE, CSA (Canada), EAC (Belarus, Kazakhstan, Russia), SASO (Saudi Arabia), UL1778 (USA) |
Built-in fan | Yes |
Housing material | Metal |
Display type | LCD |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 50 °C |
Operating relative humidity (H-H) | 0 - 95% |
Technical details |
---|
Output frequency | 50/60 Hz |
Sustainability certificates | RoHS, ENERGY STAR |
Cooling |
---|
Cooling type | Active |
Built-in fan | Yes |
Weight & dimensions |
---|
Package width | 19.8" (502.9 mm) |
Package depth | 23.5" (596.9 mm) |
Package height | 9.6" (243.8 mm) |
Weight | 28 lbs (12.7 kg) |
Width | 17.3" (438.2 mm) |
Package weight | 44.1 lbs (20 kg) |
Height | 3.5" (88.9 mm) |
Depth | 15.6" (397 mm) |
Packaging data |
---|
Rack mount kit | Yes |
Manual | Yes |
Cables included | Output power cable, RS-232, USB cable |
Package width | 19.8" (502.9 mm) |
Package depth | 23.5" (596.9 mm) |
Package height | 9.6" (243.8 mm) |
Package weight | 44.1 lbs (20 kg) |
Logistics data |
---|
Products per master (outer) case | 1 pc(s) |
Certificates |
---|
Certification | CE, CSA (Canada), EAC (Belarus, Kazakhstan, Russia), SASO (Saudi Arabia), UL1778 (USA) |
Packaging content |
---|
Rack mount kit | Yes |
Manual | Yes |
Cables included | Output power cable, RS-232, USB cable |