Tripp Lite Metered ATS / Auto Transfer Switch PDU systems enable redundant power configurations for network devices with a single input cord connection. Set of two ATS inputs support connection to separate PRIMARY and SECONDARY power sources. The ATS normally maintains continuous output to connected equipment derived from the primary input. If the primary input fails or becomes unstable, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources to support a variety of advanced redundant power networking applications. Enables fault-tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time, similar to Tripp Lite SmartOnline series. ATS configurations utilizing separate mains circuits, backup generators and even out-of-phase power sources are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front panel current meter offers selectable 4 segment voltage, amperage and kilowatt loading information. - 208V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous) - Provides a redundant power option for critical networking equipment with a single input power cord - Digital display with selection button reports voltage, amperage and kilowatt loading information in four output segments (Segment 1: 8 C13 & 1 C19 outlets / Segment 2: 8 C13 & 1 C19 outlets / Segment 3: L6-30R outlet / Segment 4: total output of all outlets combined) - 19 built-in outlets (16 C13, 2 C19, 1 L6-30R) - Set of two 10 ft. / 3m NEMA L6-30P input cables support connection to separate PRIMARY and SECONDARY power sources - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output as sourced from the secondary input cable until power on the primary input is restored and stable - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a 2 UPS environment, the primary input must be connected to an online double conversion UPS similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - Super-fast switchover between primary and secondary power sources occurs in 1-5 milliseconds - Front panel LEDs confirm power availability on both input lines - TAA Compliant Version Available - Order Tripp Lite PDUMH30HVATAA

 

Specification:

 

Design
PDU typesSwitched
MountingHorizontal
Product colourBlack
CertificationUL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico)
Rack capacity2U
Housing materialMetal
Ports & interfaces
AC outlets quantity19 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler, NEMA L6-30R
Power plugNEMA L6-30P
Features
Cable length118.1" (3 m)
LED indicatorsYes
CertificationUL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico)
Ergonomics
Cable length118.1" (3 m)
LED indicatorsYes
Power
Nominal input voltage208 V
Nominal output voltage208 V
Maximum current30 A
AC input frequency60 Hz
Weight & dimensions
Dimensions (WxDxH)17.5 x 12.5 x 3.46" (445 x 318 x 88 mm)
Weight13.7 lbs (6.21 kg)
Width17.5" (444.5 mm)
Depth12.5" (317.5 mm)
Height3.5" (88.9 mm)
Package width16.8" (426.7 mm)
Package depth19.9" (505.5 mm)
Package height7.8" (198.1 mm)
Package weight19.4 lbs (8.8 kg)
Packaging data
Package width16.8" (426.7 mm)
Package depth19.9" (505.5 mm)
Package height7.8" (198.1 mm)
Package weight19.4 lbs (8.8 kg)
Operational conditions
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Sustainability certificatesRoHS
Logistics data
Products per master (outer) case1 pc(s)
Country of originTaiwan