Sidebar Sidebar Sidebar

PDUMH30ATNET - Tripp Lite PDU SWITCHED ATS 120V 30A 24 5-15/20R; 1 L5-30R 2 L5-30P 2URM

Write a Review
$2,387.02
$1,326.12
(You save $1,060.90 )

Have questions?

Adding to cart… The item has been added
SKU: PDUMH30ATNET
Availability: In Stock
Weight: 19.50 LBS
Shipping: Calculated at Checkout
46C566DB-4644-460E-8DA7-038C0B9646AB E06A9D60-42A9-4459-8131-FA3002495928
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. - 120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 24A) - ATS features provide redundant power for critical network equipment with a single input power cord - Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface - Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional ENVIROSENSE sensor - 25 switched outlets (24 5-15/20R & 1 L5-30R) - 2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth - Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable - Highly reliable solid-state switching enables fast 1-5 millisecond trasfer between primary and secondary inputs - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Compatible with optional ENVIROSENSE temperature monitor - Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized - Front panel LEDs confirm power availability on both input lines - TAA Compliant Version Available - Order Tripp Lite PDUMH30ATNETAA

 

Specification:

 

Design
PDU typesMetered
MountingHorizontal
Product colourBlack
CertificationUL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico)
Rack capacity2U
Housing materialMetal
Ports & interfaces
AC outlets quantity18 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugNEMA L6-30P
Features
Cable length143.7" (3.65 m)
LED indicatorsYes
CertificationUL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico)
Ergonomics
Cable length143.7" (3.65 m)
LED indicatorsYes
Power
Nominal input voltage208-240 V
Nominal output voltage208-240 V
Maximum current30 A
AC input frequency50 - 60 Hz
Weight & dimensions
Dimensions (WxDxH)17.5 x 12.5 x 3.46" (444 x 318 x 88 mm)
Weight13.7 lbs (6.21 kg)
Width17.5" (444.5 mm)
Depth12.5" (317.5 mm)
Height3.5" (88.9 mm)
Package width16.7" (424.2 mm)
Package depth19.8" (502.9 mm)
Package height7.8" (198.1 mm)
Package weight15.8 lbs (7.17 kg)
Packaging data
Package width16.7" (424.2 mm)
Package depth19.8" (502.9 mm)
Package height7.8" (198.1 mm)
Package weight15.8 lbs (7.17 kg)
Operational conditions
Storage temperature (T-T)-15 - 50 °C
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Sustainability certificatesRoHS
Logistics data
Master (outer) case width16.7" (424.2 mm)
Master (outer) case length19.8" (502.9 mm)
Master (outer) case height7.8" (198.1 mm)
Master (outer) case gross weight15.8 lbs (7.17 kg)
Products per master (outer) case1 pc(s)
Country of originTaiwan

Customers Also Viewed