Sidebar Sidebar Sidebar

PDUMH15ATNET - Tripp Lite PDU SWITCHED ATS 120V 15A 5-15R 8 OUTLET 2 5-15P HORIZONTAL 1URM

Write a Review
$1,349.51
$749.73
(You save $599.78 )

Have questions?

Adding to cart… The item has been added
SKU: PDUMH15ATNET
Availability: In Stock
Weight: 16.38 LBS
Shipping: Calculated at Checkout
46C566DB-4644-460E-8DA7-038C0B9646AB E06A9D60-42A9-4459-8131-FA3002495928
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. - 120V 15A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 12A continuous) - Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord - Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface - Digital display continuously reports total output power consumption in amps - 8 switched NEMA 5-15R outlets - 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth - Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds - DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols - Compatible with optional ENVIROSENSE temperature monitor - Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized - Front panel LEDs confirm power availability on both input lines - TAA Compliant Version Available - Order Tripp Lite PDUMH15ATNETAA

 

Specification:

 

Design
TypeSingle-phase
PDU typesMetered, Switched
MountingHorizontal
DisplayLCD
Product colourBlack
Rack capacity1U
Housing materialMetal
Ports & interfaces
AC outlets quantity8 AC outlet(s)
AC outlet typesNEMA 5–15R
Power plugNEMA 5–15P
Serial ports quantity1
Features
Cable length144.1" (3.66 m)
LED indicatorsYes
Ergonomics
Cable length144.1" (3.66 m)
LED indicatorsYes
DisplayLCD
Power
Maximum power1520 W
Nominal input voltage120 V
Nominal output voltage100 - 127 V
Maximum current15 A
AC input frequency50/60 Hz
Weight & dimensions
Weight11 lbs (4.99 kg)
Width17.5" (444.5 mm)
Depth14.5" (368.3 mm)
Height1.75" (44.4 mm)
Package width20.8" (528.3 mm)
Package depth23.3" (591.8 mm)
Package height5.3" (134.6 mm)
Package weight17.1 lbs (7.74 kg)
Packaging data
Package width20.8" (528.3 mm)
Package depth23.3" (591.8 mm)
Package height5.3" (134.6 mm)
Package weight17.1 lbs (7.74 kg)
Packaging content
Cables includedAC
ManualYes
Rack mount kitYes
Operational conditions
Storage temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 95%
Operating altitude0 - 118110.2" (0 - 3000 m)
Technical details
Sustainability complianceYes
Sustainability certificatesRoHS
Logistics data
Master (outer) case width20.8" (528.3 mm)
Master (outer) case length23.3" (591.8 mm)
Master (outer) case height5.3" (134.6 mm)
Master (outer) case gross weight17.1 lbs (7.74 kg)
Products per master (outer) case1 pc(s)
Country of originTaiwan

Customers Also Viewed