PDU20SWHVIEC10ATNET - Cyberpower 200-240V 1U LCD (2) IEC C20 PLUGS 10FT CORDS 10R OUTLETS (8) IEC C13 / (2) IEC C

Write a Review
$1,473.93
$818.85
(You save $655.08 )

Have questions?

Adding to cart… The item has been added
SKU: PDU20SWHVIEC10ATNET
Availability: In Stock
Weight: 8.38 LBS
Shipping: Calculated at Checkout
PDU types: Switched
Product colour: Black
Rack capacity: 1U
Housing material: Metal
AC outlets quantity: 10 AC outlet(s)
AC outlet types: C13 coupler C19 coupler
Power plug: C20 coupler
Serial ports quantity: 1
Ethernet LAN (RJ-45) ports: 1
Management platform: SNMP/HTTP
Nominal input voltage: 200-240 V
Nominal output voltage: 200-240 V
Maximum current: 20 A
AC input frequency: 50 - 60 Hz
Dimensions (WxDxH): 17 x 9.3 x 1.75 (433 x 236.2 x 44.5 mm)
Operating temperature (T-T): 0 - 45 °C
Storage temperature (T-T): -15 - 45 °C
Operating altitude: 0 - 157480.3 (0 - 4000 m)
Non-operating altitude: 0 - 590551.2 (0 - 15000 m)
Sustainability certificates: RoHS
46C566DB-4644-460E-8DA7-038C0B9646AB E06A9D60-42A9-4459-8131-FA3002495928
The CyberPower PDU20SWHVIEC10ATNET, 10-outlet 1U rack mount switched auto transfer switch (ATS) power distribution unit (PDU), provides 200-240V / 20A output. The PDU distributes unfiltered electrical pass-through to 10 IEC-320 (8) C13 / (2) C19 receptacles from redundant IEC-320 C20 plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. The PDU20SWHVIEC10ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the ATS PDU. The switched outlet receptacles can be managed individually or collectively over the network the CyberPower Management Console /web browser and the RJ45 Ethernet port for network connection or, locally, using the LCD controls. Using the CyberPower Management Console, outlets can be turned on, turned off, or recycled on demand or at programmed times, to address multiple needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads. Additionally, the CyberPower Management Console provides real-time remote monitoring of PDU vitals and event logging to review historical power conditions, such as input voltages, load levels, and outlet status. Automatic event notifications can be sent to designated users when power events occur, via Email, SMS Text, or SNMP Trap. The LCD provides local monitoring of the PDU and on/off control the outlets. Perform load management by using the display to measure the electrical current (displayed in amperes) used by connected equipment. The LCD can also display input and output voltages, to diagnose potential issues with input AC power. Active power consumption (displayed in kilowatts) and hardware and firmware versions are also viewable on the LCD screen. Designed for datacenters and other demanding electrical applications, the PDU20SWHVIEC10ATNET has a rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL60950_1 and CSA C22.2 certified by ETL and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.