Sidebar Sidebar Sidebar

APDU10451ME - APC NETSHELTER RACK PDU ADVANCED, METERED, 14.4KW, 3PH, 208V, 50A, CS8365C, 42 O

Write a Review
$5,109.19
$2,838.44
(You save $2,270.75 )

Have questions?

Adding to cart… The item has been added
SKU: APDU10451ME
Availability: In Stock
Weight: 25.60 LBS
Shipping: Calculated at Checkout
46C566DB-4644-460E-8DA7-038C0B9646AB E06A9D60-42A9-4459-8131-FA3002495928
APC NetShelter Rack PDU Advanced, Metered, 14.4kW, 3PH, 208V, 50A, CS8365C, 42 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. RoHS

 

Specification:

 

Design
TypeSingle-phase
PDU typesMetered, Switched
DisplayLCD
Product colourBlack
Ports & interfaces
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) ports2
Features
Cable length70.9" (1.8 m)
Security algorithms56-bit AES
Management features
Management platformNMC
Ergonomics
Cable length70.9" (1.8 m)
DisplayLCD
Power
Maximum power40 W
Nominal input voltage208 V
Nominal output voltage208 V
Power protection featuresOverload
Maximum current50 A
Load capacity14400 VA
AC input frequency50/60 Hz
Number of phases3
Weight & dimensions
Weight24.5 lbs (11.1 kg)
Width2.2" (56 mm)
Depth2.95" (75 mm)
Height70.1" (1780 mm)
Package width10.3" (262 mm)
Package depth5.2" (132 mm)
Package height78" (1980 mm)
Package weight31.1 lbs (14.1 kg)
Packaging data
Package width10.3" (262 mm)
Package depth5.2" (132 mm)
Package height78" (1980 mm)
Package weight31.1 lbs (14.1 kg)
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating temperature (T-T)23 - 140 °F
Operating altitude0 - 120000" (0 - 3048 m)
Non-operating altitude0 - 600000" (0 - 15240 m)
Technical details
Sustainability certificatesRoHS
Security
Security algorithms56-bit AES

Customers Also Viewed