Sidebar Sidebar Sidebar

APDU10351ME - APC NETSHELTER RACK PDU ADVANCED, METERED, 8.6KW, 3PH, 208V, 30A, L21-30P, 42 OU

Write a Review
$3,425.60
$1,903.11
(You save $1,522.49 )

Have questions?

Adding to cart… The item has been added
SKU: APDU10351ME
Availability: In Stock
Weight: 23.59 LBS
Shipping: Calculated at Checkout
46C566DB-4644-460E-8DA7-038C0B9646AB E06A9D60-42A9-4459-8131-FA3002495928
APC NetShelter Rack PDU Advanced, Metered, 8.6kW, 3PH, 208V, 30A, L21-30P, 42 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected.

 

Specification:

 

Design
On/off switchNo
TypeSingle-phase
PDU typesSwitched
MountingVertical
DisplayLCD
Product colourBlack
CertificationCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Rack capacity0U
Ports & interfaces
AC outlets quantity48 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Features
CertificationCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Daisy chainYes
Ergonomics
DisplayLCD
Power
Nominal input voltage208 V
Nominal output voltage208 V
Output voltage208 V
Maximum current24 A
Maximum total current draw per phase24 A
Maximum input current per phase30 A
Load capacity8600 VA
AC input frequency50/60 Hz
Weight & dimensions
Weight20.7 lbs (9.4 kg)
Width2.2" (56 mm)
Depth2.95" (75 mm)
Height70.1" (1780 mm)
Package width8.19" (208 mm)
Package depth4.57" (116 mm)
Package height78" (1980 mm)
Package weight27.3 lbs (12.4 kg)
Packaging data
Package width8.19" (208 mm)
Package depth4.57" (116 mm)
Package height78" (1980 mm)
Package weight27.3 lbs (12.4 kg)
Operational conditions
Operating temperature (T-T)23 - 140 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating altitude0 - 120000" (0 - 3048 m)
Non-operating altitude0 - 600000" (0 - 15240 m)

Customers Also Viewed