Sidebar Sidebar Sidebar

APDU10151SM - APC NETSHELTER RACK PDU ADVANCED, SWITCHED METERED OUTLET, 5.0KW, 1PH, 208V, 30A

Write a Review
$6,462.32
$3,590.18
(You save $2,872.14 )

Have questions?

Adding to cart… The item has been added
SKU: APDU10151SM
Availability: In Stock
Weight: 21.60 LBS
Shipping: Calculated at Checkout
46C566DB-4644-460E-8DA7-038C0B9646AB E06A9D60-42A9-4459-8131-FA3002495928
APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 5.0kW, 1PH, 208V, 30A, L6-30P, 40 Outlet APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 40 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded by breaker to simplify deployment. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. Maximum Outlet Density All models include 40, 42, or 48 outlets to accommodate even the highest density of devices, allow for more installation flexibility, and provide room for growth within the PDUs power capacity limits. Space Saving With such high outlet counts and power capacity, NetShelter Advanced Rack PDUs are designed to maximize space with their single width form factor, often allowing for fewer PDUs to accommodate the same number of devices and power requirements. High Power Capacity Models now available to provide up to 34.6kW (derated to 80% capacity per National Electric Code (NEC) for North America) and up to 43.5kW for other countries to ensure support for most any density deployment and help minimize the number of PDUs needed to do so. APC Locking Power Cord Compatible Free up space and secure power cords between rack-mount PDUs and attached IT equipment with this easy-to-use cord retention method. Optional AP8700 power cords will fit into any standard IEC receptacle or power inlet; the "locking" feature is enabled when used with NetShelter Rack PDU Advanced to reduce the probability of accidental power cord disconnect. Circuit Breaker Monitoring Allows total load across each circuit breaker to be monitored for potential overload and can be configured to provide notification in the event of a circuit breaker trip. Alternating Phase NetShelter Rack PDU Advanced incorporates an alternating phase design on 3 phase models whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU. This alternating phase layout facilitates better power cord management and more intuitive load balancing versus traditional PDU solutions where outlets are grouped by phase at the top, middle, and bottom of the PDU. 60ºC (140ºF) Operating Temperature Rated and approved to operate up to 60C (140F) at full load, NetShelter Rack PDU Advanced ensures reliability and availability even in today's high density deployments. Power Sharing Rack PDUs cascaded together via the two ethernet ports on each PDU allow Network Management Cards (NMC) to continue functioning in the event of an AC power loss to a given PDU. Network communication is uninterrupted, attached sensors still operate, and alarm traps remain available. Hydraulic Magnetic Circuit Breakers Provide increased availability by maintaining trip current over a wide temperature range. Live Swap Network Management Card The Network Management Card (NMC) can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Color Coded Outlets To simplify deployment, outlets on the PDUs are color coded by breaker on 1 phase models and color coded and/or labeled by breaker and input phase on 3 phase models. Environmental Sensor Support Two environmental sensor ports allow for optional sensors (sold separately) to be connected. Sensors available within the NetSelter Rack PDU Advanced portfolio include temperature, temperature/humidity, temperature (3 sensors)/humidity, rope leak detection, and a door contact switch. Also available is an expansion hub to allow connection of up to three sensors providing the ability to manage six separate sensors from one rack PDU. Sensor availability expected late 2022. Wide Offer Breadth Metered, Switched, and Metered-by-Outlet with Switching functionality are available across all power configurations ranging from 5kW up to 34.6kW to meet the need for most deployments. Network Cascading Connect and manage up to 32 PDUs from a single IP address to simplify and speed PDU deployment while reducing networking costs associated with having a dedicated network connection for each PDU. US Based Manufacturing US based manufacturing enables better product availability and ability to offer configure-to-order (CTO) products (optional and subject to pricing and leadtimes) including different cord lengths, plug types, and PDU chassis color. Dual Rated For data center deployments across multiple regions, select models are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment. Flexible PDU Mounting With pre-installed mounting pegs, NetShelter Rack PDU Advanced can be quickly installed in the toolless mounting holes of the rear accessory channel in a NetShelter SX and many 3rd party cabinets. Mounting pegs can be repositioned to the side of the PDU to rotate the orientation of the outlets 90 degrees and face the back of the cabinet for better clearance from device chassis or mounting rails. 4-in-1 Combination Outlets Offering unparalleled flexibility, 4-in-1 combination outlets which can be used as either C13 or C19 enable a single PDU outlet layout to support various rack layouts and configurations. In addition, the same 4-in-1 combination outlets also serve as high temperature C15 and C21 outlets for devices with C16 and C22 power cords. With 4-in-1 combination outlets redeployment of a PDU with new rack layout or configuration is easy and straightforward, often preventing the need to remove and discard a PDU upon IT refresh. Color LCD Display NetShelter Rack PDU Advanced provides a rich color LCD display for local management and control at the rack. Dual Network Ports A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% Metering Accuracy Providing the same level of accuracy as a utility company meter by adhering to IEC 62053-21 class 1, 1% metering accuracy provides peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Gigabit Ethernet Connectivity Provides Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web and SNMP. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time.

 

Specification:

 

Design
On/off switchYes
TypeSingle-phase
PDU typesSwitched
MountingVertical
DisplayLCD
Product colourBlack
Form factorRackmount
Regulatory ApprovalsCSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Rack capacity0U
Ports & interfaces
USB ports quantity1
AC outlets quantity40 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugNEMA L6-30P
Ethernet LAN (RJ-45) ports2
Features
Cable length118.1" (3 m)
LED indicatorsActivity, Network, Power
Daisy chainYes
Surge protectionYes
Colour-coded outletsYes
Security algorithms128-bit AES,192-bit AES,256-bit AES,DES,MD5,SNMP,SNMPv2,SNMPv3
Password protectionYes
Compatible productsCompatible with most NetShelter SX enclosures and third-party racks
Reset buttonYes
Management features
Firmware upgradeable viaNetwork, USB
Firmware upgradeableYes
MonitoringCurrent, Humidity, Power, Temperature, Voltage
Outlet controlLock-out, Recycle, Turn off, Turn on
Ergonomics
Cable length118.1" (3 m)
LED indicatorsActivity, Network, Power
DisplayLCD
Compatible productsCompatible with most NetShelter SX enclosures and third-party racks
Power
Maximum power5000 W
Nominal input voltage200-240 V
Nominal output voltage208 V
Power protection featuresOverload
Maximum current30 A
Maximum total current draw per phase24 A
Load capacity4992 VA
AC input frequency50/60 Hz
Number of phases1
Weight & dimensions
Weight17 lbs (7.7 kg)
Width2.2" (56 mm)
Depth2.95" (75 mm)
Height58.7" (1490 mm)
Package width8.19" (208 mm)
Package depth4.57" (116 mm)
Package height67.7" (1720 mm)
Package weight21.4 lbs (9.7 kg)
Packaging data
Package width8.19" (208 mm)
Package depth4.57" (116 mm)
Package height67.7" (1720 mm)
Package weight21.4 lbs (9.7 kg)
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating temperature (T-T)23 - 140 °F
Operating altitude0 - 120000" (0 - 3048 m)
Non-operating altitude0 - 600000" (0 - 15240 m)
Technical details
Sustainability certificatesRoHS
Security
Security algorithms128-bit AES,192-bit AES,256-bit AES,DES,MD5,SNMP,SNMPv2,SNMPv3
Password protectionYes

Customers Also Viewed