APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Specification:
Design |
---|
PDU types | Switched |
Product colour | Black |
Certification | cUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, UL, VCCI A |
Ports & interfaces |
---|
AC outlets quantity | 48 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Input connection type | IEC 309 60A 3P+PE |
Features |
---|
Cable length | 72" (1.83 m) |
LED indicators | Yes |
Certification | cUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, UL, VCCI A |
Management features |
---|
Monitoring | Current |
Ergonomics |
---|
Cable length | 72" (1.83 m) |
LED indicators | Yes |
Power |
---|
Nominal input voltage | 208 V |
Nominal output voltage | 208 V |
Power protection features | Overload |
Maximum current | 60 A |
Maximum total current draw per phase | 48 A |
Maximum input current per phase | 60 A |
Load capacity | 17300 VA |
AC input frequency | 50 - 60 Hz |
Weight & dimensions |
---|
Dimensions (WxDxH) | 2.2 x 2.01 x 72" (56 x 51 x 1829 mm) |
Weight | 35.1 lbs (15.9 kg) |
Package weight | 44.1 lbs (20 kg) |
Package dimensions (WxDxH) | 8.7 x 4.41 x 84.6" (221 x 112 x 2149 mm) |
Packaging data |
---|
Package weight | 44.1 lbs (20 kg) |
Package dimensions (WxDxH) | 8.7 x 4.41 x 84.6" (221 x 112 x 2149 mm) |
Operational conditions |
---|
Operating temperature (T-T) | 0 - 45 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 5 - 95% |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 118110.2" (0 - 3000 m) |
Non-operating altitude | 0 - 590551.2" (0 - 15000 m) |
Technical details |
---|
Sustainability certificates | RoHS |