Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 20A, 208V, (21) C13 & (3) C19 APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager. Includes : CAN Port Terminator , Installation guide , Locking input power cord , Rack Mounting brackets , Safety guide , Serial configuration cable Metering-by-Outlet capability Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning.
Availability - Remote Individual Outlet Control Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment). - Metering-by-Outlet capability Individual outlet level power metering provides a more granular view of the power distributed to equipment within the enclosure. It also provides the ability to analyze component power trends and perform capacity planning. - Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability) - Power Delays Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly. - Local Current Monitoring Display The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only) - Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits. (Note: Only available with units with local current monitoring feature) - Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only) - Network Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements. - Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Agility - Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Specification:
Design |
---|
PDU types | Switched |
Product colour | Black |
Certification | cUL,FCC Part 15 A,ICES-003,UL,VCCI A |
Rack capacity | 0U |
Ports & interfaces |
---|
AC outlets quantity | 24 AC outlet(s) |
Power plug | NEMA L21-20P |
Features |
---|
Cable length | 118.1" (3 m) |
Certification | cUL,FCC Part 15 A,ICES-003,UL,VCCI A |
Ergonomics |
---|
Cable length | 118.1" (3 m) |
Power |
---|
Nominal input voltage | 208 V |
Nominal output voltage | 208 V |
Maximum current | 20 A |
AC input frequency | 50 - 60 Hz |
Weight & dimensions |
---|
Dimensions (WxDxH) | 2.2 x 2.01 x 72" (56 x 51 x 1829 mm) |
Weight | 15.7 lbs (7.14 kg) |
Package weight | 20.7 lbs (9.41 kg) |
Package dimensions (WxDxH) | 6.38 x 4.65 x 80.2" (162 x 118 x 2038 mm) |
Packaging data |
---|
Package weight | 20.7 lbs (9.41 kg) |
Package dimensions (WxDxH) | 6.38 x 4.65 x 80.2" (162 x 118 x 2038 mm) |
Operational conditions |
---|
Operating temperature (T-T) | -5 - 45 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 5 - 95% |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 118110.2" (0 - 3000 m) |
Non-operating altitude | 0 - 590551.2" (0 - 15000 m) |
Technical details |
---|
Sustainability certificates | RoHS |