AL400ULACM - Altronix 8FUSE OUT ACCESS PWR SPLY

Write a Review
$577.98
$321.10
(You save $256.88 )

Have questions?

Adding to cart… The item has been added
SKU: AL400ULACM
Availability: In Stock
Weight: 11.10 LBS
Shipping: Calculated at Checkout
Product colour: Gray
AC outlets quantity: 8 AC outlet(s)
Output voltage: 12 V
AC input voltage: 115 V
AC input frequency: 60 Hz
Weight: 11.1 lbs (5.03 kg)
Weight (imperial): 11.1 lbs
Dimensions (WxDxH): 12.2 x 4.53 x 15.5 (311 x 115 x 394 mm)"
46C566DB-4644-460E-8DA7-038C0B9646AB E06A9D60-42A9-4459-8131-FA3002495928
Model AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled power limited fuse protected Fail-Safe and/or Fail-Secure outputs with a total of 12VDC @ 4 amp or 24VDC @ 3 amp of continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Features Power Supply/Charger: - 12VDC or 24VDC selectable output. - 4 amp @ 12VDC or 3 amp @ 24VDC of continuous supply current output. - Class 2 Rated power limited output. - 115VAC 60Hz, 1.9 amp input. - Filtered and electronically regulated outputs. - Short circuit and thermal overload protection. - Built-in charger for sealed lead acid or gel type battery backup. - Maximum charge current .7 amp. - Zero voltage drop upon transfer to battery backup. - AC input and DC output LED indicators. - AC fail supervision (form "C" contact rated @ 1 amp 28VDC). - Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC). Access Power Controller: - Eight (8) Access Control System outputs. - Eight (8) fuse protected Fail-Safe and/or Fail-Secure 12VDC or 24VDC power outputs. - Any power output may be converted to dry form "C" relay output. - Eight (8) fuse protected 12VDC auxiliary power outputs (unswitched). - Red LEDs indicate outputs are triggered (relays energized). - Eight (8) Access Control System trigger inputs. - Eight (8) normally open (NO) inputs. - Eight (8) open collector inputs. - Any combination of the above. - Fire Alarm Disconnect: - Fire Alarm Disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs. - Normally open (NO) or normally closed (NC) dry contact input. - Polarity reversal input FACP signaling circuit. - Fire Alarm trigger LED indicates that the Fire Alarm Disconnect has been activated. - Fire Alarm output relay for triggering auxiliary reporting devices (form "C" contact rated @ 1 amp 28VDC).

Customers Also Viewed