Specification:
Power | |
---|---|
Output frequency | 50/60 Hz |
Output power | 5400 W |
Input operation voltage (min) | 176 V |
Input operation voltage (max) | 276 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Efficiency | 94% |
Power factor | 0.9 |
Output voltage Total Harmonic Distortion (THD) | 2% |
Input current Total Harmonic Distortion (THD) | 5% |
Crest factor | 3:1 |
Output power capacity | 6 kVA |
Input frequency | 40/70 Hz |
Performance | |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Number of input phases | 1 |
LED indicators | Yes |
Noise level | 45 dB |
Features | |
Output frequency | 50/60 Hz |
UPS topology | Double-conversion (Online) |
Waveform | Pure sine |
Number of input phases | 1 |
Output power | 5400 W |
Input operation voltage (min) | 176 V |
Input operation voltage (max) | 276 V |
Output operation voltage (min) | 200 V |
Output operation voltage (max) | 240 V |
Efficiency | 94% |
Power factor | 0.9 |
Output voltage Total Harmonic Distortion (THD) | 2% |
Noise level | 45 dB |
Input current Total Harmonic Distortion (THD) | 5% |
Crest factor | 3:1 |
Output power capacity | 6 kVA |
Input frequency | 40/70 Hz |
Ports & interfaces | |
USB port | Yes |
AC outlets quantity | 11 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler, Terminal |
Power plug | Terminal |
USB 2.0 ports quantity | 1 |
RS-232 ports | 1 |
Battery | |
Battery technology | Sealed Lead Acid (VRLA) |
Typical backup time at half load | 11 min |
Hot-swap battery | Yes |
Automatic battery test | Yes |
Design | |
Rack capacity | 3U |
Form factor | Rackmount/Tower |
LED indicators | Yes |
Product colour | Black |
Safety | IEC/EN 62040-1, UL 1778 |
Certification | IEC/EN 62040-1, UL 1778, IEC/EN 62040 -2, FCC Class A, IEC/EN 62040-3 (Performance), CE, CB report (TUV), UL |
Display type | LCD |
Operational conditions | |
Operating temperature (T-T) | 0 - 40 °C |
Technical details | |
Output frequency | 50/60 Hz |
Sustainability certificates | ENERGY STAR |
Harmonized System (HS) code | 85078000 |
Weight & dimensions | |
Weight | 105.8 lbs (48 kg) |
Width | 17.3" (440 mm) |
Height | 5.12" (130 mm) |
Depth | 27" (685 mm) |
Packaging data | |
Rack mount kit | Yes |
Bundled software | Intelligent Power Software suite |
Management card included | Yes |
Logistics data | |
Harmonized System (HS) code | 85078000 |
Certificates | |
Safety | IEC/EN 62040-1, UL 1778 |
Certification | IEC/EN 62040-1, UL 1778, IEC/EN 62040 -2, FCC Class A, IEC/EN 62040-3 (Performance), CE, CB report (TUV), UL |
Other features | |
Interface | USB, RS232 |
Nominal output voltage | 230 V |
Nominal input voltage | 230 V |
Packaging content | |
Rack mount kit | Yes |
Bundled software | Intelligent Power Software suite |